Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes as well as in closed installation ducts. Only for signal and control circuits.
Harmonised single core for domestic and industrial application. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Harmonised single core for domestic and industrial application. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Harmonised, zero halogen single core for internal wiring. Zero halogen compound makes this type suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Harmonised, zero halogen single core for internal wiring. Zero halogen compound makes this type suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Harmonised, zero halogen single core with improved fire characteristics for internal wiring. Zero halogen compound makes this type suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Harmonised, zero halogen single core with improved fire characteristics for internal wiring. Zero halogen compound makes this type suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed and protected installation in devices, control cabinets and in or on lighting equipment.
Harmonised, zero halogen single core with improved fire characteristics for internal wiring. Zero halogen compound makes this type suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed and protected installation in devices, control cabinets and in or on lighting equipment.
Multi-standard, heat resistant single core for internal wiring. The multiple-standard design makes them adequate for to be commercialised worldwide without technical barriers, except the sections not covered by some standard. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Multi-standard, heat resistant single core for internal wiring. The multiple-standard design makes them adequate for to be commercialised worldwide without technical barriers, except the sections not covered by some standard. For fixed and protected installation in devices, control cabinets and in or on lighting equipment. For installation in pipes on, in and under plaster as well as in closed installation ducts.
Installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. For fixed installation in air, in ducts or cable tray, in pipes as well as embedded in concrete or masonry. Outdoor laying only permitted when protected from direct sunlight and other external impacts. No ground laying without protection.
Flexible single core power cable with improved fire characteristics for fixed installations. Particularly suitable for installations with limited room and/or with a lot of bends with short radius. For fixed installation indoors, on cable trays, in pipe, in conduits or similar system. Outdoor laying only permitted when protected from direct sunlight and other external impacts.
Power cable with reinforced sheath for domestic or industrial application where no mechanical damage is to be expected. For fixed installation in open air, in ducts or cable tray as well as in pipes. No ground laying without protection.
Armoured power cable with improved fire characteristics for domestic or industrial application where additional protection against mechanical damage is required. For fixed installation in open air, in ducts or cable tray as well as in pipes. Suitable for direct ground installation without protection.
Armoured signalling and control cable with improved fire characteristics for domestic or industrial application where additional protection against mechanical damage is required. For fixed installation in open air, in ducts or cable tray as well as in pipes. Suitable for direct ground installation without protection.
Armoured installation cable with improved fire characteristics for domestic and industrial application where additional protection against mechanical damage is required. For fixed installation in air, in ducts or cable tray as well as in pipes. Outdoor laying only permitted when protected from direct sunlight and other external impacts. No ground laying without protection.
Power cable with aluminium conductor with reinforced outer sheath for domestic or industrial application where no mechanical damage is to be expected. This cable is longitudinally watertight preventing water propagation along the cable. For fixed installation in open air, in ducts or cable tray as well as in pipes. Suitable for direct ground installation with or without protection
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation in air, in ducts or cable tray, in pipes as well as embedded in concrete or masonry. Outdoor laying of non-UV resistant type only permitted when protected from direct sunlight and other external impacts. UV resistant version on request. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected.
Power and control cable. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Power and control cable with concentric copper conductor. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Power and control cable with concentric copper conductor. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Power and control cable. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Power and control cable. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Power cable with aluminium conductor and concentric copper conductor. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts where mechanical damage is not expected.
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors, in air, concrete or masonry. Outdoor laying only permitted when protected from direct sunlight and other external impacts
Zero halogen power cable with copper conductor and improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Zero halogen power cable with concentric copper conductor and improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Flexible and halogen-free power and control cable with improved fire characteristics for fixed installations in industrial or domestic environment and public buildings. Particularly suitable for installations with limited room and/or with a lot of bends with short radius. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions.
Flexible power cable with improved fire characteristics for fixed installations. Particularly suitable for installations with limited room and/or with a lot of bends with short radius. For fixed installation indoors, on cable trays, in pipe, in conduits or similar system. Outdoor laying only permitted when protected from direct sunlight and other external impacts.
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation in air, in ducts or cable tray, in pipes as well as embedded in concrete or masonry. Outdoor laying of non-UV resistant type only permitted when protected from direct sunlight and other external impacts. UV resistant version on request. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation in air, in ducts or cable tray, in pipes as well as embedded in concrete or masonry. Outdoor laying of non-UV resistant type only permitted when protected from direct sunlight and other external impacts. UV resistant version on request. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where additional protection against mechanical damage is required. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation in air, in ducts or cable tray. Suitable for direct ground installation without protection.
Flexible power and control cable for fixed installations in industrial or domestic environment and public buildings. Particularly suitable for installations with limited room and/or with a lot of bends with short radius. It can be buried or installed in conduit as well as outdoors without requiring additional protection
Flexible and halogen-free power and control cable with improved fire characteristics for fixed installations in industrial or domestic environment and public buildings. Particularly suitable for installations with limited room and/or with a lot of bends with short radius. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions.
Zero halogen aluminium power cable with improved fire characteristics for fixed installation. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. Outdoor laying only permitted when protected from direct sunlight and other external impacts.
Armoured, zero halogen installation cable with improved fire characteristics for domestic and industrial application where additional protection against mechanical damage is required. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation in open air, in ducts or cable tray as well as in pipes. This type is suitable for direct ground installation without protection.
Power, control and installation cable for domestic or industrial application where no mechanical damage is to be expected. For fixed installation in open air, in ducts or cable tray as well as in pipes. No ground laying without protection.
Lead sheathed, steel tape armoured and hydrocarbon resistant power cable with improved fire characteristics for domestic or industrial application. For fixed installation in open air, in ducts or cable tray as well as in pipes. This type is suitable for direct ground installation without protection.
Armoured, zero halogen power cable with improved fire characteristics for applications where additional protection against mechanical damage is required. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors or outdoors. Suitable for direct ground installation without protection.
Armoured, zero halogen power cable with improved fire characteristics for applications where additional protection against mechanical damage is required. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors or outdoors. Suitable for direct ground installation without protection.
Highly flexible single core conductor for use in portable earthing and short circuit-devices. Particularly prior to field maintenance or repair work on high-voltage systems, in railway systems, failing current equipment and in distribution networks.
For use in electrical grounding systems, on insulators for overhead transmission and distribution applications.
For use in electrical grounding systems, on insulators for overhead transmission and distribution applications.
For use in electrical grounding systems, on insulators for overhead transmission and distribution applications.
Flexible battery connection cable for indoors and outdoors, in dry as well as wet location on motorized vehicles, or battery powered equipment such as forklifts, field conveyors etc. Also as high quality booster cables.
Medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on challenging routes and in difficult conditions. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground without additional protection and in cable ducts if no posterior mechanical damage is to be expected. This constructions is particularly suitable for underground installation.
Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground and in cable ducts where mechanical damage is not expected. This constructions is particularly suitable for underground installation.
Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground and in cable ducts where mechanical damage is not expected. This constructions is particularly suitable for underground installation.
Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground and in cable ducts where mechanical damage is not expected. This constructions is particularly suitable for underground installation.
The good installation properties of this cable make installation easy, even on challenging routes and in difficult conditions. For fixed installation indoors and outdoors, in ground, in water and in cable ducts where mechanical damage is not expected. Outdoor laying only permitted when protected from direct sunlight and other external impacts.
Medium voltage cable for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground without additional protection, in water and in cable ducts if no posterior mechanical damage is to be expected.
Medium voltage cable for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is longitudinally water tight preventing water propagation along the cable. For fixed installation indoors and outdoors, in ground without additional protection, in water and in cable ducts if no posterior mechanical damage is to be expected.
Medium voltage cable for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on challenging routes and in difficult conditions. For fixed installation indoors and outdoors, in ground, in water and in cable ducts where mechanical damage is not expected. Outdoor laying only permitted when protected from direct sunlight and other external impacts.
Armoured medium voltage cable for power stations, industrial applications and distribution networks where additional protection against mechanical damage is required during installation, laying and operation. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts.
Armoured medium voltage cable with aluminium conductor for power stations, industrial applications and distribution networks where additional protection against mechanical damage is required and in the case of increased tensile forces during installation, laying and operation. For fixed installation indoors and outdoors, in ground, in water, in concrete and in cable ducts.
Halogen-free medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks. It is suitable for installation in tunnels and underground transport systems as well as in buildings with increased fire protection. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment.
Halogen-free medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks. It is suitable for installation in tunnels and underground transport systems as well as in buildings with increased fire protection. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment.
Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions. These cables may be used for fixed installation indoors and outdoors, on racks, direct burial or in conduits. This constructions is particularly suitable for underground installation due to the longitudinal water-tightness.
Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions. These cables may be used for fixed installation indoors and outdoors, on racks, direct burial or in conduits. This constructions is particularly suitable for underground installation due to the longitudinal water-tightness.
Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions. These cables may be used for fixed installation indoors and outdoors, on racks, direct burial or in conduits. This constructions is particularly suitable for underground installation due to the longitudinal water-tightness.
Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions.
Fire resistant power cable. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Fire resistant power cable. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Fire resistant power cable with concentric copper conductor. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Fire resistant power cable with concentric copper conductor. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Fire resistant power cable. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Outdoor laying only permitted when protected from direct sunlight and other external impacts. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Fire resistant power cable. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation indoors, in air or concrete. Underground installation is allowed provided that the cable is installed in a sufficiently drained tube (no water accumulation).
Collectively screened installation cable for telecommunications and information processing systems. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation
Collectively screened installation cable for telecommunications and information processing systems. Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. For fixed installation
Zero halogen, flexible single core power cable with improved fire characteristics for use in photovoltaic systems. For the cabling between the solar modules and as extension cable between the module strings and the DC/AC inverter
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations.
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations.
Instrumentation cables with steel wire armoring for use in environments with electromagnetic interference. These cables are widely used in the petrochemical industry, in instrumentation and control applications for instrumentation, control and communication applications. Cables are suitable for direct burial.
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations.
Zero halogen instrumentation cable with improved fire characteristics for transmission of analogue and digital signals in instrument and control systems where no mechanical damage is to be expectedFor fixed installation indoors and outdoors, on racks, trays, in conduits, in dry and wet locations. No ground laying without protection. Indoor installation is allowed in areas where the construction product regulations (CPR) acc. to EN 50575 of fire class are not required.
Zero halogen instrumentation cable with improved fire characteristics for transmission of analogue and digital signals in instrument and control systems where no mechanical damage is to be expected.Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors and outdoors, on racks, trays, in conduits, in dry and wet locations. No ground laying without protection. Indoor installation is allowed in areas where the construction product regulations (CPR) acc. to EN 50575 of fire class are not required.
Instrumentation cables with double steel tape armoring are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. They are well adapted to underground use in industrial applications where an additional mechanical protection is required.
Instrumentation cables with double steel tape armoring are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. They are well adapted to underground use in industrial applications where an additional mechanical protection is required.
Instrumentation cables are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries.
Instrumentation cables for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries.
PVC control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
Screened PVC control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
Flexible power, process control and instrumentation cable with inner sheath for industry, machinery and outdoor environment. The cable is resistant to UV-irradiation, to most commonly used chemicals and to oil and grease. For fixed installation or flexible applications, with free movement without forced motion and without tensile stress. Not suitable for constant motion.
Flexible and screened power, process control and instrumentation cable with inner sheath for industry, machinery and outdoor environment. The cable is resistant to UV-irradiation, to most commonly used chemicals and to oil and grease. For fixed installation or flexible applications, with free movement without forced motion and without tensile stress. Not suitable for constant motion.
Flexible collectively screened control cable with improved fire characteristics for various applications. For installation in conduit, buried or open air.
Steel wire-reinforced, universal measurement and control cable in tool machinery, plant installation, power stations and in data equipment. For fixed laying and flexible applications without tensile stress and without defined cable routing. The cable is largely resistant to acids, bases and specified types of oil. The braided screen offers best possible protection against mechanical damage.
Zero halogen control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
UV resistant zero halogen control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
Zero halogen screened control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
UV resistant zero halogen screened control cable with improved fire characteristics for various applications. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation or flexible applications indoors, with free movement without forced motion and without tensile stress.
Flexible motor power supply cable for frequency converter controlled AC drives in industries or wind turbines. This cable type, that incorporate a special screen and have a symmetrical distribution of the protective conductor (3x... + 3G...), are adequate for facilities where is necessary avoid the interferences of electromagnetic waves of high frequency of nearby circuits, as variation engines of speed.
Flexible motor power supply cable with improved fire characteristics for frequency converter controlled AC drives in industries or wind turbines. This cable type, that incorporate a special screen and have a symmetrical distribution of the protective conductor (3x... + 3G...), are adequate for facilities where is necessary avoid the interferences of electromagnetic waves of high frequency of nearby circuits, as variation engines of speed.
Flexible motor power supply cable with improved fire characteristics for frequency converter controlled AC drives in industries or wind turbines. This cable type, that incorporate a special screen and have a symmetrical distribution of the protective conductor (3x... + 3G...), are adequate for facilities where is necessary avoid the interferences of electromagnetic waves of high frequency of nearby circuits, as variation engines of speed.
Flexible zero halogen motor power supply cable with improved fire characteristics for frequency converter controlled AC drives in industries or wind turbines. This cable type, that incorporate a special screen and have a symmetrical distribution of the protective conductor (3x... + 3G...), are adequate for facilities where is necessary avoid the interferences of electromagnetic waves of high frequency of nearby circuits, as variation engines of speed.
Flexible motor power supply cable with improved fire characteristics for frequency converter controlled AC drives in industries or wind turbines. This cable type, that incorporate a special screen and have a symmetrical distribution of the protective conductor (3x... + 3G...), are adequate for facilities where is necessary avoid the interferences of electromagnetic waves of high frequency of nearby circuits, as variation engines of speed.
Zero halogen Industrial electronic cable with improved fire characteristics for transmission of signals and measurements measurements in the symmetric circuits of the control and regulation technology and transmission of data and process information in computer systems. For fixed installation. Outdoor laying only permitted with UV protection.
Industrial electronic cable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology and transmission of data and process information in computer systems. For fixed installation. Outdoor laying only permitted with UV protection.
Screened electronic cable for signal transmission between electronic devices, in computer systems or process control units with increased electromagnetic compatibility requirements.
Halogen-free and environmentally data transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology, in fire vulnerable areas and facilities with high concentration of people and property values, for lossless transmission of data and signals. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.Industrial electronic cable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology and transmission of data and process information in computer systems.
Halogen-free and environmentally data transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology, in fire vulnerable areas and facilities with high concentration of people and property values, for lossless transmission of data and signals. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.Industrial electronic cable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology and transmission of data and process information in computer systems.
Harmonised flexible zero halogen cable for AC charging stations. Excellent resistance to the effects of oil, grease, dust and water. Excellent resistance to heavy mechanical stress. Very good resistance to cold and other weather influences. Compatible with all major connectors. Suitable for indoor and outdoor use.
Rubber-sheathed, flexible cable. For connecting of power tools, mobile units and machines for medium mechanical requirements in dry and humid rooms, for outdoor use, in explosive areas, in commercial and agricultural plants and on construction lots.
Rubber-sheathed, flexible cable. For connecting of power tools, mobile units and machines for medium mechanical requirements in dry and humid rooms, for outdoor use, in explosive areas, in commercial and agricultural plants and on construction lots
Harmonised rubber sheathed flexible cable with high temperature resistance. For use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential, such as heavy-duty connection of equipment between pumps and generators, and for temporary power generation. For medium mechanical loads, in dry or damp locations, as well as outdoors, in areas with explosion risks, wind turbines or fixed installation on plaster in temporary buildings.
Zero halogen, rubber sheathed flexible cable with improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment
The cables are suitable for fixed installation and flexible operation as power supply cables to motors, distribution boards, etc., for heavy duty underground mining, tunnel building, open-cast mining or for use in quarries and similar applications with specific requirements to EMC. Permitted for applications according to DIN VDE 0118.
Flexible heavy-duty rubber cable for high mechanical load. For flexible use and fixed installation open-cast mining applications, in quarries, on construction sites and similar applications, with heavy mechanical stresses.
Rubber-sheathed, flexible connecting cable designed to transmit high currents between the welding generator and the electrode in various applications with a voltage rating of up to 100V
Rubber sheathed, flexible single core for wiring of machines, tools, devices, appliances and control cabinets for use in railway vehicles and buses. It can be used for short circuit-proof and short-to-ground-proof installations up to 1 kV.
Zero halogen, rubber sheathed, flexible single core for wiring of machines, tools, devices, appliances and control cabinets for use in railway vehicles and buses. It can be used for short circuit-proof and short-to-ground-proof installations up to 1 kV. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment.
Flat, PVC sheathed, flexible power and control cable for use on festoon systems and for connecting moveable parts of machine tools especially on hoisting devices, lifts, cranes and gantries. For bending in one level only. Overlaying cables is not recommended when installing.
PVC control cable, with steel supporting elements for movable control panels and consoles.
Heavy duty flat, rubber sheathed, flexible power and control cable for use on festoon systems and for connecting moveable parts of machine tools especially on hoisting devices, lifts, cranes and gantries. For bending in one level only. Overlaying cables is not recommended when installing.
Flat, zero halogen, flexible power and control cable for use on festoon systems and for connecting moveable parts of machine tools especially on hoisting devices, lifts, cranes and gantries.
Rubber-sheathed flexible power and control cable for basic reeling application under medium mechanical stresses. For use in hoists, transporting machines and conveyors, in power chains, as drum and drag cables and as hawsers.
Special-sheathed flexible power and control cable for reeling application for high and very high mechanical load
These cables are intended for connection of switchgear cubicles and for connection of mobile transformer substations to the overhead line. Also usable for connection of pantographs in locomotives and trains. When laying and during operation care should be taken to protect them against excessive mechanical stresses. In other respects, DIN VDE 0298-3 applies. Usable on railway vehicles having hazard level HL3 acc. to DIN EN 45545-1(2013).
These cables are intended for use as short length connection in switchgear or transformer houses where a very small bending radius is required as well as power cables on mining equipment and alongside conveyor belts. Can also be used for low-speed energy chains, drum applications or to supply energy to large electrical applications and drives via energy carriers sustems. When laying and during operation, care should be taken to protect them from excessive mechanical stress.
Flexible medium voltage reeling cable for transmission of energy, under high or extreme mechanical stresses, e.g. high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stresses. Mainly for mobile equipment, e.g. fast-moving container cranes, cranes, large mobile equipment and excavators.
Flexible medium voltage reeling cable for power supply with cable guidance in different levels, e.g. reel axis in travel direction. Especially for high and extreme mechanical stress. For connection of large material handling machines in open pit mines, different crane types in harbours, shipyards, stacker/reclaimers in stockyards and other industrial areas
Flexible medium voltage reeling cable for the combined transmission of energy and data, under high or extreme mechanical stresses, e.g. high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stresses
Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance, small amount of smoke, halogen free, flamm- retardant, soldering iron resistant, easy to strip and process, flexible.
Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance, for protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers
Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, easy to strip and process, heat pressure and highly abrasion resistant, soldering iron resistant, flexible.
Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, soldering iron resistant, easy to strip and process, compatible to all common resins and varnishes, flexible.
The products feature exceptional performance, quality and durability. They ensure the reliable transmission of energy, signals and data even in demanding outdoor conditions.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. The single core cables are intended for fix installation in rail vehicles.
Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire, easy to strip and flexible. The single core cables are intended for fix installation in rail vehicles
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Screened halogen free, electron- beam cross- linked cables with improved behaviour in case of fire. The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service.
Power and Battery cable, for use in road vehicle applications. Excellent resistance to high and low temperature, ozone, UV and weathering resistance, resistant to pressure at high temperature, motor oil, fuels and hydrolysis,
Power and Battery cable, for use in road vehicle applications. Excellent resistance to high and low temperature, ozone, UV and weathering resistance, resistant to pressure at high temperature, motor oil, fuels and hydrolysis,
Cable, for use in road vehicle applications. Excellent resistance to high and low temperature, ozone, UV and weathering resistance, resistant to pressure at high temperature, motor oil, fuels and hydrolysis, flame retardant
Fire resistant ship and offshore cable for fixed installations on ships and offshore platforms in a wide range of power supply and control applications. Suitable for use in all demanding marine environment conditions such as muddy, dry, wet or oily conditions meeting the requirements of NEK 606.
Fire resistant ship and offshore cable for fixed installations on ships and offshore platforms in a wide range of power supply and control applications. Suitable for use in all demanding marine environment conditions such as muddy, dry, wet or oily conditions meeting the requirements of NEK 606.
Fire resistant ship and offshore cable for fixed installations on ships and offshore platforms in a wide range of power supply and control applications. Suitable for use in all demanding marine environment conditions such as muddy, dry, wet or oily conditions meeting the requirements of NEK 606.
Flexible zero halogen power supply and control cable with improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment.
Harmonised PUR-sheathed, flexible cable. Increased durability under harsh conditions thanks to robust PUR outer sheath. These cables can be used for medium mechanical loads in dry, damp or wet environments, e.g. connection of electrical tools on building sites or in cold environments. The cable is highly oil-, abrasion- and impact resistant. Suitable for outdoor use.
For use in dry and wet environments as well as temporary outdoors under medium mechanical stress. For connection of electrical tools on building sites or in cold environments. The cable is highly oil-, abrasion- and impact resistant.
PVC installation cable with improved fire characteristics for telecommunications and information processing systems. For fixed installation indoors.
PVC telecommunication cable with improved fire characteristics for fixed installation. These cables may be used for telecommunication and information processing systems. For buildings with high concentrations of people or valuable equipment, especially in difficult evacuation conditions. Suitable for indoor applications.
Zero halogen installation cable with improved fire characteristics for telecommunications and information processing systems. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors.
Zero halogen installation cable with improved fire characteristics for telecommunications and information processing systems. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors.
Zero halogen installation cable with improved fire characteristics for telecommunications and information processing systems. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors.
Collectively screened communication cable with improved fire characteristics for use in security systems. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. For fixed installation indoors.
Collectively screened, zero halogen and armoured installation cable with improved fire characteristics for telecommunications and information processing systems where additional protection against mechanical damage is required. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. Cables are suitable for direct burial.
Outdoor fiber optic cable with central loose tube and non-metallic rodent protection for use as termination and connection cable in wide are and local area networks. For fixed installation outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Outdoor fiber optic cable with loose tubes and metallic rodent protection for use as termination and connection cable in wide are and local area networks. For fixed installation outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Universal, fire resistant fiber optic cable with corrugated steel tape armouring, rodent proof, for use as termination and connection cable in wide are and local area networks. For fixed installation indoors and outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Universal, fire resistant fiber optic cable with corrugated steel tape armouring, rodent proof, for use as termination and connection cable in wide are and local area networks. For fixed installation indoors and outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Fire resistant fiber optic cable with loose tubes and metallic rodent protection for use as termination and connection cable in wide area and local area networks. For fixed installation outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Outdoor fiber optic cable with loose tubes and metallic rodent protection for use as termination and connection cable in wide are and local area networks. For fixed installation outdoors, in ducts or conduits, in dry and wet locations. Suitable for direct ground installation without protection.
Zero halogen universal (indoors and outdoors) fibre optical cable with improved fire characteristics. Central loose tube and non metallic rodent protection for campus/backbone and structured cabling.
Lead sheathed, halogen free fibre optic outdoor cable with improved fire characteristics. For MAN (city networks) and LAN (campus/backbone), suitable for splicing technique. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations; for direct burial, especially in presence of oil and aggressive chemical substances.
Zero halogen industrial ethernet (PROFINET Type A) cable with improved fire characteristics for universal use. As data cable for the transmission of digital and analog signals for PROFINET systems, Industrial Ethernet & ICT network applications (10/100 Mbits).
Zero halogen industrial ethernet (PROFINET Type B) cable with improved fire characteristics for universal use. As data cable for the transmission of digital and analog signals for PROFINET systems, Industrial Ethernet & ICT network applications (10/100 Mbits).
Zero halogen Profibus cable with improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment. These cables are suitable for Profibus DP (Decentralized Peripherals), Profibus FMS (Fieldbus Message Specification) and also for FIP (Factory Instrumentation Protocol) applications.
Collectively screened communication cable with improved fire characteristics for telecommunications and information processing systems. The product is designed for use in building management, e.g. for decentralized control of lighting, heating, air-conditioning, ventilation, energy management, blinds, time management, locking systems etc
Zero halogen and fire retardant data transmission cable for frequencies up to 250 MHz for use installation in generic cabling systems. Ideal for all applications of class D up to E. For fixed installation indoors.
Zero halogen and fire retardant data transmission cable for frequencies up to 250 MHz for use installation in generic cabling systems. Ideal for all applications of class D up to E. For fixed installation indoors.
Data transmission cable with individual and collective screen, zero halogen, fire retardant, with rodent protection.
Data transmission cable with individual and collective screen, zero halogen, UV resistant.
Waterproof and UV-resistant data transmission cable for generic cabling systems acc. to ISO/IEC 11801 and EN 50173. Ideal for all applications of class D up to F Multimedia (Video, Data, Voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE/PoE+. For fixed installation outdoors. Suitable for direct burial if no mechanical damage is to be expected.
Signal-, control- and measuring cable for transmission of low, sensitive signals and high bit rates with high data transfer rates up to 10 Mb/s, for lossless data and signal transmission. For fixed laying and limited flexible applications with undefined cable routing and without tensile stress. Can be used in dry and humid rooms for indoor (Li2YCY) and outdoor use as well as laying directly underground (Li2YCYv).
Single core with silicone insulation for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards for operation in ambient temperatures up to +180°C.
Flexible single core with silicone insulation for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distribution boards for operation in ambient temperatures up to +180°C.
Flexible silicone single core with glass fibre braided protection for use in machines, plant construction and toolbuilding for temperatures up to +180°C.
Compensating (also referred to as compensation cables) and thermocouple extension cables are used for temperature sensing in industrial processes. In most cases thermocouples are connected to other processing instruments by connecting cables. Connecting cables are divided into compensating cables and extension cables.