Profibus DP FC LSZH UV Cca Zero halogen Profibus cable with improved fire characteristics. Zero halogen cables are suitable for installation in environments where smoke and toxic fumes may threaten life or valuable equipment |
Cu |
1 |
100 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
Profinet Type A FC LSZH Cca Zero halogen industrial ethernet (PROFINET Type A) cable with improved fire characteristics for universal use. |
Cu |
1 |
150 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
RADOX 125 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. |
Cu |
5 |
0,6/1 kV |
Eca |
125 °C |
low smoke fire retardant zero halogen |
RADOX 155 Electron beam crosslinked Isolation; excellent high temperature, low temperature, ozone, weathering and abrasion resistance. |
Cu |
5 |
0,6/1 kV |
|
155 °C |
|
RADOX UL 3271 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, easy to strip and process, heat pressure and highly abrasion resistant, soldering iron resistant, flexible. |
Cu |
5 |
0,6/1 kV |
|
125 °C |
flame retardent |
RADOX UL 3289 Excellent high temperature, low temperature, ozone and weathering resistance, flame retardant, soldering iron resistant, easy to strip and process, compatible to all common resins and varnishes, flexible. |
Cu |
5 |
0,6/1 kV |
|
150 °C |
flame retardent |
HCHM Cca EIB Collectively screened communication cable with improved fire characteristics for telecommunications and information processing systems. |
Cu |
1 |
250 V |
Cca |
70 °C |
fire retardant |
U/UTP LSOH Cca Zero halogen and fire retardant data transmission cable for frequencies up to 250 MHz for use installation in generic cabling systems. Ideal for all applications of class D up to E. For fixed installation indoors. |
Cu |
1 |
|
B2ca |
70 °C |
fire retardant zero halogen |
S/FTP Cca PiMF, Cat7 Data transmission cable with individual and collective screen, zero halogen, fire retradant. |
Cu |
1 |
|
Cca |
70 °C |
fire resistant zero halogen |
S/FTP Fca 2Y, Cat7 Data transmission cable with individual and collective screen, zero halogen, UV resistant. |
Cu |
|
|
Fca |
70 °C |
zero halogen |
S/FTP Fca PiMF, Cat7, waterproof Waterproof and UV-resistant data transmission cable for generic cabling systems. |
Cu |
1 |
|
Fca |
70 °C |
|
Z1O-J-H(St)H Cca Collectively screened, zero halogen and armoured installation cable with improved fire characteristics. |
Cu |
1 |
300 V |
Cca |
70 °C |
low smoke zero halogen fire retardant |
A-DQ(ZN)B2Y Outdoor fiber optic cable with central loose tube and non-metallic rodent protection. |
|
|
|
|
70 °C |
|
A-DQ(ZN)(SR)2Y unitube Outdoor fiber optic cable with central loose tube and metallic rodent protection. |
|
|
|
|
70 °C |
|
U-DQ(ZN)(SR)H B2ca unitube Universal, fire resistant fiber optic cable with corrugated steel tape armouring, rodent proof |
|
|
|
B2ca |
70 °C |
fire resistant flame retardent |
U-DQ(ZN)H(SR)H Cca multitube Universal, fire resistant fiber optic cable with corrugated steel tape armouring, rodent proof |
|
|
|
Cca |
70 °C |
fire resistant flame retardent |
A-DQ(ZN)H(SR)H Cca unitube Fire resistant fiber optic cable with central loose tube and metallic rodent protection. |
|
|
|
Cca |
70 °C |
fire retardant |
A-DQ(ZN)(SR)2Y multitube Outdoor fiber optic cable with central loose tube and metallic rodent protection. |
|
|
|
|
70 °C |
|
A-DQ(ZN)BHMHBY-fl Lead sheathed, halogen free fibre optic outdoor cable with improved fire characteristics. |
|
|
|
|
60 °C |
fire retardant |
JE-H(St)H Cca Zero halogen Industrial electronic cable with improved fire characteristics for transmission of signals and measurements. |
Cu |
1 |
225 V |
Cca |
70 °C |
flame retardent fire retardant zero halogen |
JE-Y(St)Y Bd Eca Industrial electronic cable for transmission of signals and measurements. |
Cu |
1 |
225 V |
Eca |
70 °C |
flame retardent |
LIYCY Cca DIN 47100 Screened electronic cable for signal transmission between electronic devices, in computer systems or process control units with increased electromagnetic compatibility requirements. |
Cu |
5 |
250 V |
Cca |
70 °C |
flame retardent fire retardant |
LIHCH DIN 47100 Halogen-free and environmentally data transmission cable, control and connecting cable. |
Cu |
5 |
250 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
LIHCH TP DIN 47100 Halogen-free and environmentally data transmission cable, control and connecting cable. |
Cu |
5 |
250 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
Li2YCY/Li2YCYv Signal-, control- and measuring cable for transmission of low, sensitive signals and high bit rates. |
Cu |
2 |
250 V |
Eca |
70 °C |
flame retardent |
YSLY/LIYY PVC halogen control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant |
YSLCY/LIYCY Screened PVC control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant |
YSLY 1 kV Flexible power, process control and instrumentation cable with inner sheath. |
Cu |
5 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
YSLYCY 1 kV Flexible and screened power, process control and instrumentation cable with inner sheath. |
Cu |
5 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
LIYCY-J Cca, 1 kV Flexible collectively screened control cable with improved fire characteristics for various applications. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant zero halogen |
YSLYQY/LIYYSY Steel wire-reinforced, universal measurement and control cable. |
Cu |
5 |
300/500 V |
Eca |
70 °C |
flame retardent |
HSLH/LIHH Cca Zero halogen control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
HSLCH/LIHCH Cca Zero halogen screened control cable with improved fire characteristics for various applications. |
Cu |
5 |
300/500 V |
Cca |
70 °C |
fire retardant low smoke zero halogen |
2XSL(St)CYK-J Flexible motor power supply cable for frequency converter. |
Cu |
5 |
0,6/1 kV |
Eca |
90 °C |
flame retardent |
2XSL(St)CH-J EMC Cca direct burial Flexible motor power supply cable with improved fire characteristics for frequency converter. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant low smoke zero halogen |
2XSL(St)CH-J EMC Cca Flexible motor power supply cable with improved fire characteristics for frequency converter. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant low smoke zero halogen |
ROZ1-K EMC Cca Flexible zero halogen motor power supply cable with improved fire characteristics for frequency converter. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
Li-2XY(CuB)CY-J Cca Flexible motor power supply cable with improved fire characteristics for frequency converter. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
Compensation and Thermocouple Compensating and thermocouple extension cables are used for temperature sensing in industrial processes. |
|
1, 2, 5 |
|
|
|
|
SiD (SiA) Single core with silicone insulation. |
Cu |
1 |
300/500 V |
|
180 °C |
|
SiF Flexible single core with silicone insulation. |
Cu |
5 |
300/500 V |
|
180 °C |
|
SiF GL Flexible silicone single core with glass fibre braid. |
Cu |
5 |
300/500 V |
|
180 °C |
|
Pyro Signal RF 1h30 Collectively screened installation cable for telecommunications and information processing systems. Cables with intrinsic fire resistance. |
Cu |
1 |
225 V |
|
90 °C |
fire resistant |
Pyro Telecom RF 1h30 Collectively screened installation cable for telecommunications and information processing systems. Cables with intrinsic fire resistance. |
Cu |
1 |
225 V |
|
90 °C |
fire resistant |
XVB NBN Installation cable with improved fire characteristics for various industrial and domestic applications. |
Cu |
1, 2 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
XV flex Flexible single core power cable with improved fire characteristics for fixed installations. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
EXVB NBN Power cable with reinforced sheath for domestic or industrial application. |
Cu |
1, 2 |
0,6/1 kV |
Eca |
90 °C |
flame retardent |
EXAVB NBN Armoured power cable with improved fire characteristics for domestic or industrial application. |
Cu |
1, 2 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
SXAVB NBN Armoured signalling and control cable with improved fire characteristics. |
Cu |
1 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
XFVB NBN Armoured signalling and control cable with improved fire characteristics |
Cu |
1, 2 |
0,6/1 kV |
Cca |
90 °C |
fire retardant |
XGB NBN Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications. |
Cu |
1, 2 |
0,6/1 kV |
Cca |
90 °C |
zero halogen low smoke fire retardant |
EAXG Zero halogen installation cable with improved fire characteristics for various industrial and domestic applications where no mechanical damage is to be expected. |
Alu |
1, 2 |
0,6/1 kV |
|
90 °C |
fire retardant zero halogen low smoke |
NYY VDE Power and control cable. For fixed installation indoors and outdoors. |
Cu |
1, 2 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
NYCY VDE Power and control cable with concentric copper conductor. |
Cu |
1 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
NYCWY VDE Power and control cable with concentric copper conductor. |
Cu |
2 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
NAYY VDE Power and control cable with aluminium conductor. |
Alu |
1, 2 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
E-AYY ÖVE Power and control cable with aluminium conductor. |
Alu |
1, 2 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
NAYCWY VDE Power cable with aluminium conductor and concentric copper conductor. |
Alu |
1, 2 |
0,6/1 kV |
Eca |
70 °C |
flame retardent |
N2XH Zero halogen power cable with copper conductor and improved fire characteristics. |
Cu |
1, 2 |
0,6/1 kV |
Cca, B2ca |
90 °C |
low smoke zero halogen fire retardant |
N2XCH Zero halogen power cable with concentric copper conductor and improved fire characteristics. |
Cu |
1, 2 |
0,6/1 kV |
Cca, B2ca |
90 °C |
zero halogen low smoke fire retardant |
N2XH flex Flexible and halogen-free power and control cable with improved fire characteristics for fixed. |
Cu |
5 |
0,6/1 kV |
B2ca, Cca |
90 °C |
fire retardant low smoke zero halogen |
YMVK Cca flex Flexible single core power cable with improved fire characteristics for fixed installations. |
Cu |
5 |
0,6/1 kV |
Eca |
90 °C |
flame retardent fire retardant |
YMz1K rss NEN Zero halogen installation cable with improved fire characteristics for various industrial and domestic application. |
Cu |
1, 2 |
0,6/1 kV |
Cca, B2ca |
90 °C |
low smoke zero halogen fire retardant |
YMz1K NEN Zero halogen installation cable with improved fire characteristics for various industrial and domestic application. |
Cu |
1, 2 |
0,6/1 kV |
B2ca |
90 °C |
low smoke zero halogen fire retardant |
Z10-YMz1Kas Cca-B2ca NEN Armoured safety signalling and control cable. |
Cu |
1 |
0,6/1 kV |
Cca, B2ca |
90 °C |
zero halogen fire retardant flame retardent |
RV-K Flexible power and control cable for fixed installations in industrial or domestic environment and public buildings. |
Cu |
5 |
0,6/1 kV |
Eca |
90 °C |
flame retardent |
RZ1-K (AS) Flexible and halogen-free power and control cable with improved fire characteristics for fixed installations in industrial or domestic environment and public buildings. |
Cu |
5 |
0,6/1 kV |
Cca, B2ca |
90 °C |
low smoke zero halogen fire retardant |
RZ1 (AS) AL Zero halogen aluminium power cable with improved fire characteristics for fixed installation. |
Alu |
2 |
0,6/1 kV |
B2ca, Cca |
90 °C |
low smoke zero halogen fire retardant |
RZ1MZ1-K Armoured, zero halogen installation cable with improved fire characteristics for domestic and industrial application. |
Cu |
5 |
0,6/1 kV |
Cca |
90 °C |
low smoke zero halogen fire retardant |
U1000 R2V NFC Power, control and installation cable for domestic or industrial application. |
Cu |
1, 2 |
0,6/1 kV |
Eca |
90 °C |
flame retardent |
U1000 RGPFV Lead sheathed, steel tape armoured and hydrocarbon resistant power cable with improved fire characteristics |
Cu |
1, 2 |
0,6/1 kV |
|
90 °C |
fire retardant |
CU/XLPE/LSZH/AWA/LSZH BS Armoured, zero halogen power cable with improved fire characteristics. |
Cu |
2 |
0,6/1 kV |
|
90 °C |
fire retardant low smoke zero halogen |
CU/XLPE/LSZH/SWA/LSZH BS Armoured, zero halogen power cable with improved fire characteristics. |
Cu |
2 |
0,6/1 kV |
|
90 °C |
low smoke zero halogen fire retardant |
ESUY earthing conductor Highly flexible single core conductor for use in portable earthing and short circuit-devices. |
Cu |
6 |
|
|
70 °C |
flame retardent |
EXeCVB IEC 60332-3-24 NBN Medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks |
Cu |
2 |
8,7/15 kV |
|
90 °C |
fire retardant |
EAXeCWB NBN Medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks |
Alu |
2 |
8,7/15 kV |
|
90 °C |
|
BAXeCWB NBN medium voltage cable with reduced insulation thickness for power stations, industrial applications and distribution networks. |
Alu |
2 |
8,7/15 kV |
|
90 °C |
|
N2XSY VDE Medium voltage cable for power stations, industrial applications and distribution networks. |
Cu |
2 |
6/10 kV, 12/20 kV or 18/30 kV |
|
90 °C |
flame retardent |
N2XS(F)2Y VDE Medium voltage cable for power stations, industrial applications and distribution networks. |
Cu |
2 |
6/10 kV, 12/20 kV or 18/30 kV |
|
90 °C |
|
NA2XS(F)2Y VDE Medium voltage cable for power stations, industrial applications and distribution networks. |
Alu |
2 |
6/10 kV, 12/20 kV or 18/30 kV |
|
90 °C |
|
N2XSEY VDE Medium voltage cable for power stations, industrial applications and distribution networks. |
Cu |
2 |
6/10 kV |
|
90 °C |
flame retardent |
NYFGY VDE Armoured medium voltage cable for power stations, industrial applications and distribution networks. |
Cu |
2 |
3,6/6 kV |
|
70 °C |
flame retardent |
NAYFGY VDE Armoured medium voltage cable for power stations, industrial applications and distribution networks. |
Alu |
2 |
3,6/6 kV |
|
70 °C |
flame retardent |
RG26H1M16 Cca 105°C Halogen-free medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks. |
Cu |
2 |
|
Cca |
105 °C |
low smoke zero halogen fire retardant |
2XS(F)H B2ca Halogen-free medium voltage cable with improved fire characteristics for power stations, industrial applications and distribution networks. |
Cu |
2 |
|
B2ca |
90 °C |
low smoke zero halogen fire retardant |
EXeCGB B2ca NBN Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. |
Cu |
2 |
8,7/15 kV |
B2ca |
90 °C |
low smoke zero halogen fire retardant |
RHZ1 Cca Halogen-free medium voltage cable with improved fire characteristics. May be used as power supply cable in public networks and industrial plants. |
Cu |
2 |
6/10 kV, 12/20 kV or 18/30 kV |
Cca |
90 °C |
low smoke zero halogen fire retardant |
RE-2Y(St)Y-fl Cca pairs For transmission of analogue and digital signals in instrument and control systems. |
Cu |
2 |
500 V |
Cca |
70 °C |
flame retardent fire retardant |
RE-2Y(St)YSWAY-fl Cca PiMF For transmission of analogue and digital signals in instrument and control systems. |
Cu |
2 |
500 V |
Cca |
70 °C |
flame retardent fire retardant |
RE-2Y(St)YSWAY-fl Cca pairs For transmission of analogue and digital signals in instrument and control systems. |
Cu |
2 |
500 V |
Cca |
70 °C |
fire retardant flame retardent |
RE-2X(St)H Cca or B2ca pairs Zero halogen instrumentation cable with improved fire characteristics for transmission of analogue and digital signals in instrument and control systems. |
Cu |
2 |
300 V |
Cca, B2ca |
90 °C |
low smoke zero halogen fire retardant |
RE-2X(St)H Cca or B2ca PiMF Zero halogen instrumentation cable with improved fire characteristics for transmission of analogue and digital signals in instrument and control systems. |
Cu |
2 |
300 V |
Cca, B2ca |
90 °C |
low smoke zero halogen fire retardant |
NF M 87 – 202 EGFA Instrumentation cables with double steel tape armoring are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. |
Cu |
2 |
500 V |
|
90 °C |
flame retardent fire retardant |
NF M 87 – 202 EIFA Instrumentation cables with double steel tape armoring are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. |
Cu |
2 |
500 V |
|
90 °C |
flame retardent fire retardant |
NF M 87 – 202 EGSF Instrumentation cables are used for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. |
Cu |
2 |
500 V |
|
90 °C |
flame retardent fire retardant |
NF M 87 – 202 EISF Instrumentation cables for the transmission of AC or DC analogue signals in the papermaking, chemical and petrochemical industries. |
Cu |
2 |
500 V |
|
90 °C |
flame retardent fire retardant |
H05V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. |
Cu |
5 |
300/500 V |
Eca |
70 °C |
flame retardent |
H07V-K Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. |
Cu |
5 |
450/750 V |
Eca |
70 °C |
flame retardent |
H07V-R Harmonised single core for fixed and protected installation in devices, control cabinets and in or on lighting equipment. |
Cu |
2 |
450/750 V |
Eca |
70 °C |
flame retardent |
H05Z-K Harmonised, zero halogen single core for internal wiring. |
Cu |
5 |
300/500 V |
Eca |
90 °C |
flame retardent |
H07Z-K Harmonised, zero halogen single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07Z1-K Harmonised, zero halogen single core with improved fire characteristics for internal wiring. |
Cu |
5 |
450/750 V |
Cca, B2ca |
70 °C |
zero halogen flame retardent low smoke |
H05V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
H07V2-K Tri rated Multi-standard, heat resistant single core for internal wiring. |
Cu |
5 |
450/750 V |
Eca |
90 °C |
flame retardent |
NSHXAFöu Zero halogen, rubber sheathed, flexible single core for wiring of machines, tools, devices, appliances and control cabinets for use in railway vehicles and buses |
Cu |
5 |
1,8/3 kV |
Cca |
90 °C |
flame retardent zero halogen |